Construction elements
  • Introduction
  • Product overview
  • Contact

Construction elements

ThyssenKrupp provides architects, civil engineers and planners with concentrated expertise from a single source. ThyssenKrupp Steel Europe not only makes the material but also supplies customized steel products for building and cold room construction.

Important products in the building area are Hoesch® sandwich panels and single-shell steel profiles in various shapes for use in roofs, walls and ceilings. In addition to their principal role, these products also perform additional functions such as noise abatement, heat insulation and fire protection and permit modern architectural design. One example from the range of products is the Hoesch Additive Floor® – a unique decking system for parking garages and multistory buildings. It combines the advantages of traditional steel construction with the benefits of composite construction in a system that is much less expensive than other construction methods.

Our depth of experience in cold room construction allows us to offer products which meet the highest demands on insulation and hygiene. With its ems and Isocab brands, ThyssenKrupp offers tailored solutions for all cold and freezer room applications in the form of sandwich elements consisting of steel face sheets and a rigid PUR foam core. Together with optimized doors, these elements help minimize cold losses and make a significant contribution to the cost efficiency of cold storage and freezer facilities.

Steel can be used to meet special structural requirements. One example of our continuous efforts to develop innovative products for the construction industry is Solartec, an energy-generating photovoltaic roof and facade system. As well as generating energy it also performs the “normal” functions of a building shell. The colors included in the Reflections collection give architects and planners new design possibilities, allowing them to blend large industrial buildings aesthetically into the landscape. And with the new bimodular steel sandwich element Hoesch Matrix®, prestigious, high-quality facades can be created which were previously mainly the preserve of curtain wall facades.

Sandwich elements/panels

Sandwich elements/panels
Sandwich elements/panels
Component designation Technical data Sales
  Thickness [mm] Length [m] Installation [mm] Heat transfer coefficient (U) W/m2K ThyssenKrupp Steel Europe/ Hoesch Bausysteme Isocab
* With different insulating materials depending on specified fire protection class.
** Other lengths on inquiry.
Hoesch isowand integral® 60–120 2–20 1,000 ** 0.40–0.20
 
Hoesch isowand vario® 60–140 2–20 1,000 0.40–0.17
 
Hoesch® isowand design 60–100 2–22 1,000 0.37–0.22
 
Hoesch isodach mono® 95–155 2–24 1,000 0.39–0.20
 
Hoesch isodach integral® 75–155 2–24 1,000 0.52–0.19
 
Hoesch isowelle® 64–104 2–20 1,000 0.47–0.27
 
Hoesch isowelle® Dach 64–104 2–20 1,000 0.47–0.27
 
Hoesch isorock® vario * 80–200 2–16 1,000 0.52–0.21
 
Hoesch® Thermowand 1000/Thermowand 40–120 2–24 1,000–1,175 0.58–0.20
 
Hoesch® Thermowand TL 66–96 2–24 1,000 0.47–0.29
 
Hoesch® Thermodach 75–130 2–24 1,000 0.52–0.24
 
Hoesch isorock®/ isorock® akustik 60–200 2–16 1,000 0.65–0.21
 
Hoesch isorock integral® D 95–155 2–18 1,000 0.44–0.27
 
 
ems product series PU PU 40–PU 220 40–220 2–20 ** 1,176 0.56–0.11
 
ems product series PUD PUD 40–PUD 220 40–220
2–20 ** 1,176 0.56–0.11
 
 
Isocab wall IND 40–220 40–220 2–20 1,120–1,180 0.53–0.10  
Isocab wall FC 60–80 60–80 2–20 1,000–1,055 0.38–0.28  
Isocab roof C3 30–120 30–120 2–20 1,040 0.78–0.30  
Isocab Decaroc 60–300 MIWO 60–300 2–15 1,030–1,170 0.69–0.14  
 
Isocab clean room wall CRA 8 PUR 80 0.3–5.7 300–1,200 0.28  
Isocab clean room wall CRA 8 MIWO 80 0.3–5.7 300–1,200 0.45  
top

Hoesch Matrix®

Hoesch Matrix®
Hoesch Matrix®
Component designation Technical data Sales
  Thickness [mm] Length [m] Installation width [mm] Profiling ThyssenKrupp Steel Europe/ Hoesch Bausysteme
        outside inside  
Contact: Chris Redmond, Key Account Hoesch Matrix®, ThyssenKrupp Steel Europe AG
Phone: +49 (0)2732 599-1348, Fax: +49 (0)2732 599-1430, Mobile: +49 (0)177 4958902,
E-mail: chris.redmond@thyssenkrupp.com
Hoesch Matrix® 80–160 1.0–6.0 600–1,000 smooth smooth/lined
top

Cold rooms

Cold rooms
Cold rooms
Component designation Technical data Sales
  Thickness [mm] Length [mm] Installation width [mm] Heat transfer coefficient
(U) W/m2K
Isocab
Isocab ISO 6–14 60–140 300–3,900 300–1,200 0.37–0.16
Isocab Minibox MH 80 900–3,000 900–2,400 0.28
top

Single-shell elements

Single-shell elements
Single-shell elements
Component designation Technical data Sales
  Profile height [mm] Maximum span [m] Arch radius R Arch length
LB[m]
Length
[m]
Installation width
[mm]
ThyssenKrupp Steel Europe/ Hoesch Bausysteme Isocab
Hoesch Additiv Floor® 205 5.8        
 
Hoesch® Arched Roof 38/106 20 4.00–30.00 m 4–24    
 
Hoesch® Roof System 2000 205 10     2–24  
 
Hoesch® polygon arch 33-40   minimum 150 mm      
 
Hoesch® trapezoidal wall profile 32–48.5       2–18 915–1,035
 
Hoesch® trapezoidal roof profile 83–158       2–24 750–1,120
 
Hoesch® acoustic trapezoidal profile 33-40       2-18 750–1,035
 
Hoesch® corrugated profile 18       2–12 1,064
 
Hoesch® liner tray 90–160       2–16 600
 
Hoesch Planeel® siding facade panel 24       0.4–8 200–400
top

Energy-generating elements

Energy-generating elements
Distributed by: FRANZEN Metall-Umformtechnik GmbH, Hausener Strasse 47-49, 56736 Kottenheim, Germany,
Phone: +49 (0)2651 4008-0
Energy-generating elements
Component designation Technical data
  Element thickness [mm] Length [m] Installation width [mm] Power output Pmax
Solartec   2.95–5.8 415–474 64/128
Solartec mono 1000 75–115 3.17–24.0 1,000 128–896
 
top

LBH Houses

LBH Houses
LBH Houses
Component designation Technical data Sales
  Total area [m2] Isocab
Isocab LBH 28 28
Isocab LBH 40 40
Isocab LBH 55 55
Isocab LBH 57 57
Isocab LBH 65 65
Isocab LBH 74 74
Isocab LBH 90 90
Isocab LBH T2 77
Isocab LBH T3A 107
Isocab LBH T3B 100
top

Doors

Doors
Doors
Component designation Technical data Sales
  Door leaf thickness [mm] Clear width [mm] Clear height [mm] Heat transfer coefficient (U) W/m2K* Isocab ThyssenKrupp Bausysteme
* The heat transfer coefficient relates to the homogenous area of the door leaf.
Isocab plant room hinged door, single-leaf 40 620–1,220 1,985–2,185  
 
Isocab plant room hinged door, double-leaf 40 1,520–2,300 1,985–2,185  
 
Isocab cold room hinged door, single-leaf 60 650–1,430 900–3,630  
 
Isocab cold room hinged door, double-leaf 80 1,250–2,330 2,000–3,630  
 
Isocab freezer room hinged door, single-leaf 60 650–1,430 900–3,630  
 
Isocab freezer room hinged door, double-leaf 80 1,250–2,330 2,000–3,630  
 
Isocab metal swing door, single-leaf 40 650–1,250 2,000–3,630  
 
Isocab metal swing door, double-leaf 40 1,100–2,330 2,000–3,630  
 
Isocab polyethylene swing door, single-leaf 15 950–1,250 2,200–3,330  
 
Isocab polyethylene swing door, double-leaf 15 1,250–2,330 2,200–3,330  
 
Isocab plant room sliding door, single-leaf 38 650–1,250 1,900–3,030  
 
Isocab plant room sliding door, double-leaf 38 1,400–2,330 2,200–3,030  
 
Isocab light cold room sliding door 60 800–2,030 1,900–3,030  
 
Isocab light freezer room sliding door 100 800–2,030 1,900–3,030  
 
Isocab cold room sliding door 60 1,430–2,930 2,130–3,630  
 
Isocab cold room sliding door 100 1,430–2,930 2,130–3,630  
 
Isocab freezer room sliding door 100 1,430–2,930 2,130–3,630  
 
Isocab freezer room sliding door 140 1,430–2,930 2,130–3,630  
 
Isocab clean room hinged door, single-leaf 40 1,067 2,133  
 
Isocab clean room hinged door, single-leaf 80 1,067 2,133  
 
Isocab clean room hinged door, double-leaf 40 1,367–1,967 2,133  
 
Isocab clean room hinged door, double-leaf 80 1,367–1,967 2,133  
 
Isocab clean room sliding door 50 900–1,800 2,250  
 
Hoesch® sectional door element with finger guard 39.5 488/610/732 2,000–20,000 0.59  
top

All construction elements listed comply with the relevant and currently valid ordinances and standards on structural use.

ThyssenKrupp Steel Europe AG

Hammerstrasse 11
57223 Kreuztal
Germany

Phone: +49 (0)2732 599-1599
Fax: +49 (0)2732 599-1271

E-mail to ThyssenKrupp Steel Europe AG

ThyssenKrupp Bausysteme GmbH

Markenvertrieb ems
Süderstrasse 12–14
23689 Pansdorf
Germany

Phone: +49 (0)4504 802-302
Fax: +49 (0)4504 802-300

E-mail to ThyssenKrupp Bausysteme GmbH

Hoesch Bausysteme GmbH

Tenschertstrasse 3
1230 Wien
Austria

Phone: +43 (0)1 615-4640
Fax: +43 (0)1 615-4630

E-mail to Hoesch Bausysteme GmbH

Isocab N.V.

Treurnietstraat 10
8531 Harelbeke – Bavikhove
Belgium

Phone: +32 (0)56 73 43-11
Fax: +32 (0)56 73 43-22

E-mail to Isocab N.V.

Websites

Further information about these products can be found on the following websites.

ThyssenKrupp Steel Europe AG Color/Construction Unit

Hoesch Bausysteme GmbH

Isocab N.V.

ReflectionsOne®

More information on color in industrial construction can be found on the ReflectionsOne® website.